- Page 2 - Page 3 - Page 4 - Page 5 - Page 6 - Page 7 - Page 8 - Page 9 - Page 10 - Page 11 - Page 12 - Page 13 - Page 14 - Page 15 - Page 16 - Page 17 - Page 18 - Page 19 - Page 20 - Page 21 - Page 22 - Page 23 - Page 24 - Page 25 - Page 26 - Page 27 - Page 28 - Page 29 - Page 30 - Page 31 - Page 32 - Page 33 - Page 34 - Page 35 - Page 36 - Page 37 - Page 38 - Page 39 - Page 40 - Page 41 - Page 42 - Page 43 - Page 44 - Page 45 - Page 46 - Page 47 - Page 48 - Page 49 - Page 50 - Page 51 - Page 52 - Page 53 - Page 54 - Page 55 - Page 56 - Page 57 - Page 58 - Page 59 - Page 60 - Page 61 - Page 62 - Page 63 - Page 64 - Page 65 - Page 66 - Page 67 - Page 68 - Page 69 - Page 70 - Page 71 - Page 72 - Page 73 - Page 74 - Page 75 - Page 76 - Page 77 - Page 78 - Page 79 - Page 80 - Page 81 - Page 82 - Page 83 - Page 84 - Page 85 - Page 86 - Page 87 - Page 88 - Page 89 - Page 90 - Page 91 - Page 92 - Page 93 - Page 94 - Page 95 - Page 96 - Page 97 - Page 98 - Page 99 - Page 100 - Page 101 - Page 102 - Page 103 - Page 104 - Page 105 - Page 106 - Page 107 - Page 108 - Page 109 - Page 110 - Page 111 - Page 112 - Page 113 - Page 114 - Page 115 - Page 116 - Page 117 - Page 118 - Page 119 - Page 120 - Page 121 - Page 122 - Page 123 - Page 124 - Page 125 - Page 126 - Page 127 - Page 128 - Page 129 - Page 130 - Page 131 - Page 132 - Page 133 - Page 134 - Page 135 - Page 136 - Page 137 - Page 138 - Page 139 - Page 140 - Page 141 - Page 142 - Page 143 - Page 144 - Page 145 - Page 146 - Page 147 - Page 148 - Page 149 - Page 150 - Page 151 - Page 152 - Page 153 - Page 154 - Page 155 - Page 156 - Page 157 - Page 158 - Page 159 - Page 160 - Page 161 - Page 162 - Page 163 - Page 164 - Page 165 - Page 166 - Page 167 - Page 168 - Page 169 - Page 170 - Page 171 - Page 172 - Page 173 - Page 174 - Page 175 - Page 176 - Page 177 - Page 178 - Page 179 - Page 180 - Page 181 - Page 182 - Page 183 - Page 184 - Page 185 - Page 186 - Page 187 - Page 188 - Page 189 - Page 190 - Page 191 - Page 192 - Page 193 - Page 194 - Page 195 - Page 196 - Page 197 - Page 198 - Page 199 - Page 200 - Page 201 - Page 202 - Page 203 - Page 204 - Page 205 - Page 206 - Page 207 - Page 208 - Page 209 - Page 210 - Page 211 - Page 212 - Page 213 - Page 214 - Page 215 - Page 216 - Page 217 - Page 218 - Page 219 - Page 220 - Flash version © UniFlip.com |
![]()
New Research Tools from WPI
Muscle Physiology
The SI-CTS200 Cell Tester can be used for single cell or larger skinned muscle fiber preparations. Translational experiments from the single living cells to the intact multi-cellular level can be accomplished. The Cell Tester provides researchers with the comprehensive ability to investigate and characterize the physiological, bio-mechanical and bio-physical properties of single isolated living cells and extend these findings to the sub- and multi-cellular level. New accessories like the Biofluorometer and Optical Sarcomere Spacing system are available for use with the Cell Tester. Page 3 The new SI-H Horizontal Tissue/Organ Bath system (SI-HTB) combines the ease of use and productivity of a traditional vertical organ bath with the more advantageous features of single tissue physiology platforms. The solid horizontal tissue bath design is ideal for combination with electrophysiology on the same platform. Intracellular measurements can share the stable solid base of the bath system. WPI's new fiber-optic based, multi-channel biofluorometer allow for tissue fluorescence measurements (calcium, NO, ROS) on the SI-HTB platform. Page 5 Now, you can design a system to meet your needs and budget. And, it is fully upgradeable in the future. The new SI-BF100 is an LED-based fluorometer for life science applications. It is ideally suited for ratiometric calcium detection (FURA-2) and ATPase detection. It also works well with voltagesensing dyes in neuroscience and any other fluorometric application. Page 6 The SI-H Compact Landgendorff needs no glass columns. It has both Langendorff and working heart perfusion modes. Page 7 The full-size SI-H Langendorff system is designed as a perfusion system for isolated, small mammalian hearts. The system includes the stainless steel sink, a small reeling pump and specially designed two-way Teflon taps. A Neely system is also available. Page 9 WPI offers a new modular design for all your favorite electronic equipment. Install up to eight units in one convenient system. This is perfect for use with the horizontal tissue baths, muscle testers and cell testers. Units available include: SI-BAM21LCB amplifier, SI-AOSUB anti-oscillation unit, SI-TCM2 temperature controller, position controller for the SI-CTS200, SI-SARCAM Laser Sarcomere Spacing system for the SI-MKB, SI-COLUB Contant Load unit, and the SI-MOTDB linear motor controller for the SI-MKB. Page 82
Live Cell Imaging
This LCI incubator has a unique, diffusion grid with air input and return vents to provide an air flow pattern for consistent, even heating, with no hot or cold spots in the chamber. The external heater can be placed far enough from the system to eliminate electrical and vibrational interference from the heater. It has a high degree of temperature precision and stability, minimal focal drift after equilibrium is achieved. With accuracy of ±0.1ºC at the sample itself, and 0.2ºC across the microscope stage, it allows for uniform heating of multiwell dishes. Page 156 For short term or long term studies of living cell cultures under a microscope or for time lapse video research, a microscope stagetop incubator is necessary. Perfect for Live Cell Imaging, STEV (the stagetop environmental control system) is a compact environmental case that houses your culture wells and fits on a microcope stage. This system offers precision control of both temperature and carbon dioxide. CO2 is measured inside the stagetop incubator, where it is most critical. Page 158
Pumps
The Nanoliter 2010 system is perfect for oocyte injection and applications in the 2.3–69nL range. It offers fast, accurate 2.3nL aliquot injections. It works with glass pipettes. Nanoliter 2010 can be combined with the Micro4 controller. Page 186 The reliable, compact MiniVacuum pump, sold with some SI-H Muscle Testers, is also available separately. Maintenance free • Minimal vibrations • Low noise • Long life (185x72x72mm) Page 185
Microfluidics
The SF-MFP pump delivers smooth, pulse-free flow of volumes from 100nL to 90µL or at rates between 250nL/min. to 10µL/min. Made of PEEK, this tiny pump is compatible with a range of solvents, solutions, buffers and reagents. With this pump, you can throw out your nut and ferrule connections. Now a proprietary connection system uses powerful magnets for leak-proof, self aligning connections that are a snap to assemble. Page 191
Surgical Supplies
The 8L BioClave Mini comes preprogrammed for basic sterilization. Choose either the 120ºC or 134ºC temperature mode, and the cycle time is fixed. This is the perfect autoclave for small spaces. Page 32
|