background image
P
arvalux standard flange/mount and shaft
General tolerance on data is +/- 10%; Values shown are at normal operating temperature unless stated.
PBL60 motor and controller pack
ages
Motor
PBL60-78
PBL60-98
PBL60-118
PBL60-138
Controller ref.
N
N
B
B
Max rated speed
rpm
4000
4000
4000
4000
Rated torque
Nm
0.11
0.22
0.32
0.44
1 minute rating
Nm
0.14
0.28
0.4
0.
Peak torque (duration 6 seconds)
Nm
0.22
0.44
0.64
0.88
DC bus voltage nominal
V
24
24
24
24
DC bus voltage min-max
V
16-32
16-32
16-32
16-32
DC bus current at no load and max rated speed
A
0.2
0.38
0.
0.6
DC bus current at rated torque and max rated speed
A
3
.
7.
10
Controller cont. current
A
7.
10
1
Controller peak current
A
10
1
20
30
PBL60 motor data
























1 0
2.0
0.0
1.0
0
1000
2000
3000
4000
speed (rpm)
multiple of continuous torque
intermittent operating region
continuous operating region
1 minute rating
Torque/speed characteristics
The controllers we supply are matched for each motor in
the range and tested as a pair with the motors during pro-
duction.
They operate from a 24V supply and have an analogue in-
put for motor speed, an input for forward/reverse direction
and a pulsed output to indicate motor speed.
Most models have an additional input for enable/disable
and an output indicating a fault condition.
·
·
·