Sensors Macro SenSorS SpecieS Order Number Price Available Diameters Response Time Detection Limit/Range Sensitivity Drift Temperature Dependent Physiological Interference Replacement Sleeves (pkg of 4) Filling Solution Start-up Kit 2 mm < 5 sec 1 NM to 80µM 2 mm < 5 sec < 100nM to 100µM 8 pA/µM 0.1pA/min Yes None #600012 #100042 #600011 2 mm < 10 sec 0.1%-100% 0.3-0.6nA/% < 1%/min Yes None #5378 #7326 $ nitric oxide iSo-nop Hydrogen peroxide iSo-Hpo-2 oxygen iSo-oXY-2 oXeLp Hydrogen Sulfide iSo-H2S-2 2 mm < 5 sec < 5nM-100µM 2 pA/nM Yes None #600016 #100084 #600015 ≤2 pA/nM <1pA/min Yes NaNO2 (10-6 or better) #5436 #7325 #5435 #5377 BIOS EN S I NG Micro SenSorS iSo-nopF200-Lxx3 iSo-nopF500-cxx iSo-nop70-Lxx3 iSo-nopF100 iSo-nopF100-L3 iSo-nop30-L3 iSo-nop3005 iSo-nop3020 iSo-nopF200 iSo-nop007 ISO-HPO-100 iSo-Hpo-100 H202 (pkg of 3) order number Species Price Fiber Diameter (µm) Tip Length2 (mm) Response Time (sec.) Lowest Detection Limit/ Range (nM) Nominal Sensitivity-New Sensor2 (pA/nM) Baseline Drift (pA/min) 1Sensor Nitric Oxide (pkg of 2) (pkg of 3) (pkg of 2) (pkg of 2) (pkg of 3) (pkg of 3) (pkg of 3) (pkg of 3) H2S 200 1-51 <5 0.2 ≥20 none 200 1-101 <5 0.2 ≥50 none 100 1-51 <5 0.2 ≥10 none 70 3 <3 1 ≥10 none 500 5–10 < 10 0.2 ≥ 20 none 30 0.5 <3 1 ≥1 none 30 2 <3 1 ≥1.5 none 30 3 <3 1 ≥1 none 7 2 <3 0.5 ≥1 none Conical tip: 7 100nm 100 1–41 <5 1 ≥1 <2.0 100 2-51 ~5 <5 1-4 <2 2 <3 0.5 ≥0.5 none available in 1mm length increments (for example, 1mm, 2mm, 3mm...). 2Sensor sensitivity varies with length and diameter. Any 10µm sensor can be purchased with a hypodermic sheath. Add a -H to the end of the part number (for example, ISO-HPO-100-H). 3L-shaped sensor for use with a tissue bath. Some nitric oxide sensors are available in custom lengths. When ordering custom lengths, use the part numbers ISO-NOPF100-Cxx or ISO-NOPF200Cxx and replace the xx with the desired length. For example, for a 1mm flexible sensor tip, the part number should be ISO-NOPF200-C01. Sensors can be ordered in the following custom lengths: 1mm, 2mm, 3mm, 4mm or 5mm. Ag/AgCl Reference Electrode Glass tip tapers to ~100µm Tip 7µm Ø Fiber Sensing Element tapers to ~100nm tip nsor Body mm long Sensor Body 60mm x < 2mm∅ Ag/AgCl flexible 100, 200 or 500µm Sensor Body Ag/AgCl 60mm x <2mm∅ 2mm or 0.5mm ~2mm ~100– 200µm 5mm 2mm 2mm 7µm or 30µm NOPNM UK: Tel: +44 (0)1462 424700 • wpiuk@wpi-europe.com ISO-NOPF World Precision Instruments ISO-NOP007, ISO-NOP30 US: Tel: 941-371-1003 • sales@wpiinc.com www.wpiinc.com Germany: Tel: +49 (0)30-6188845 • wpide@wpi-europe.com iSo-H2S-100 53 iSo-nopnM